北京航空航天大学学报 ›› 2017, Vol. 43 ›› Issue (2): 360-365.doi: 10.13700/j.bh.1001-5965.2016.0101

• 论文 • 上一篇    下一篇

激光光谱法尿素水溶液液膜多参数同步测量

石建伟1,2, 吴威1,2, 杨荟楠1,2, 郭晓龙1,2, 苏明旭1,2, 蔡小舒1,2   

  1. 1. 上海理工大学 能源与动力工程学院, 上海 200093;
    2. 上海市动力工程多相流动与传热重点实验室, 上海 200093
  • 收稿日期:2016-01-26 出版日期:2017-02-20 发布日期:2016-08-01
  • 通讯作者: 杨荟楠,E-mail:yanghuinan@usst.edu.cn E-mail:yanghuinan@usst.edu.cn
  • 作者简介:石建伟,男,硕士研究生。主要研究方向:激光光谱测量方法;杨荟楠,女,博士,副教授。主要研究方向:激光光谱测量方法与应用。
  • 基金资助:
    国家自然科学基金(51676130,51306123);博士点基金联合资助课题(20133120120008);上海市科委科研计划(13DZ2260900);上海高校青年教师培养资助计划

Simultaneous measurement of multi-parameter of liquid film for urea-water-solution by laser spectroscopy

SHI Jianwei1,2, WU Wei1,2, YANG Huinan1,2, GUO Xiaolong1,2, SU Mingxu1,2, CAI Xiaoshu1,2   

  1. 1. School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China;
    2. Shanghai Key Laboratory of Multiphase Flow and Heat Transfer in Power Engineering, Shanghai 200093, China
  • Received:2016-01-26 Online:2017-02-20 Published:2016-08-01
  • Supported by:
    National Nature Science Foundation of China (51676130, 51306123); the Joint Specialized Research Found for the Doctoral Program of Higher Education (20133120120008); Research Project of Shanghai Municipal Science and Technology (13DZ2260900); Cultivation of Young Teachers in Colleges and Universities Funded Program in Shanghai

摘要: 对溶液液膜温度、厚度和浓度进行定量分析对与之相关的工业过程至关重要,对其机理的研究中它们互相耦合,而传统的测量方法只能实现液膜的温度、厚度和浓度的单独测量。本文基于比尔-朗伯定律,提出一种尿素水溶液液膜的温度、厚度和浓度同步测量新方法,通过结合3个波长1 420、1 488和1 531 nm的激光,建立了尿素水溶液液膜的温度、厚度和浓度的同步反演模型。在此基础上,利用1 mm温控样品池验证了该方法的测量精度,结果表明,该方法测量尿素水溶液液膜厚度的平均误差为0.51%,液膜温度的平均误差为2.59%,液膜浓度的平均误差为6.32%。

关键词: 激光光谱, 液膜, 厚度, 温度, 浓度

Abstract: Quantitative analysis of liquid film temperature, thickness and mass fraction is extremely crucial to the relevant industrial processes, and these parameters are mutually coupled in the study of the mechanism for heat transfer. Temperature, thickness and mass fraction of liquid film, however, can only be determined individually by conventional measurement techniques. In this paper, a novel measurement method based on Beer-Lambert law to measure the film temperature, thickness and mass fraction of urea-water-solution simultaneously was developed by combining three lasers with different wavelengths:1 420, 1 488 and 1 531 nm. In addition, measurement accuracy of this method was validated by a sample cell with controlled temperature and 1 mm optical path length. The experimental results reveal that average relative errors of thickness, temperature and mass fraction of urea-water-solutions measured by the developed method are 0.51%, 2.59% and 6.32%, respectively.

Key words: laser spectroscopy, liquid film, thickness, temperature, mass fraction

中图分类号: 


版权所有 © 《北京航空航天大学学报》编辑部
通讯地址:北京市海淀区学院路37号 北京航空航天大学学报编辑部 邮编:100191 E-mail:jbuaa@buaa.edu.cn
本系统由北京玛格泰克科技发展有限公司设计开发