Volume 34 Issue 05
May  2008
Turn off MathJax
Article Contents
Yang Lijun, Liao Shengjie, Fu Qingfei, et al. Experiment of heat release rate of pool fire effect on water mist fire suppression[J]. Journal of Beijing University of Aeronautics and Astronautics, 2008, 34(05): 537-540. (in Chinese)
Citation: Yang Lijun, Liao Shengjie, Fu Qingfei, et al. Experiment of heat release rate of pool fire effect on water mist fire suppression[J]. Journal of Beijing University of Aeronautics and Astronautics, 2008, 34(05): 537-540. (in Chinese)

Experiment of heat release rate of pool fire effect on water mist fire suppression

  • Received Date: 30 Jan 2007
  • Publish Date: 31 May 2008
  • In order to research on fire extinguishing characteristics and rules of water mist under different heat release rate conditions, seven heptane-pan fire of different sizes were applied to single-nozzle and four-nozzle fire extinguishing experiments in the compartment of 4.6m×3.3m×4m. Thermocouple tree and gas analyzer were used to measure flame temperature and oxygen concentration around the flame during the experiment. The characteristics rules of water mist fire extinguishing under different heat release rate conditions and change rules of flame temperature field during fire extinguishing were obtained respectively. The design and test standard method of water mist fire extinguishing system and the development criteria of water mist fire extinguishing products were provided from the experiment.

     

  • loading
  • [1] 杨立军,蔡国飙,刘洪山,等.超细气水雾灭火机理研究[J].消防科学与技术,2003,22(1):11-13 Yang Lijun, Cai Guobiao, Liu Hongshan, et al. Study of theory of extinguishing of water fog and air[J]. Fire Science and Technology, 2003,22(1):11-13(in Chinese) [2] Williams F W, Beck G G, Dinenno P J, et al. Full-scale machinery space water mist test:final design validation . Naval Research Laboratory, NRL/MR/6180-99-8380, 1999 [3] Back G,Lattimer B, Beyler C, et al. Full-scale testing of water mist fire suppression systems for small machinery spaces and spaces with combustible boundaries . U.S. Coast Guard Research and Development Center, CG-D-21-99, 1999 [4] GA 400-2002,气体灭火系统及零部件性能要求和试验方法[S] GA 400-2002, Performance requirements and method of test for components of gas fire extinguishing systems[S](in Chinese) [5] GB 4351-1997,手提式灭火器通用技术条件[S] GB 4351-1997, General specifications for portable fire extinguishers[S](in Chinese)
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views(3636) PDF downloads(1040) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return