Ring artifact correction for industrial CT images

  • Received Date: 17 Nov 2006
  • Publish Date: 30 Nov 2007
  • Ring artifacts in computed tomography (CT) images are introduced by imperfect pixel channel in a detector. Ring artifacts degrade the CT image, hamper post processing and prohibit quantitative analysis. A set of algorithms that enable virtually complete ring artifact correction were proposed. Correction for pixel channel response nonuniformity was that offset and gain correction were done to compensate for response nonuniformity in the detector. Correction for projection sinogram data was that the vertical line artifacts in the sonogram were removed by a computationally efficient filter. Correction for already-reconstructed images was that the ring artifacts in the Cartesian coordinate were transformed into the vertical line artifacts in the polar coordinate and removed as sonogram correction. The procedures were created to deal with data acquired from an YXLON XRS232 9″ image intensifier. Ring artifacts were reduced significantly with minimal to negligible contamination of the underlying data.

     

  • loading
  • [1] Varian Medical Systems.PaxScan flat panel imagers 2520,4030A communications manual[M]. North Charleston: Varian Medical Systems, 2004: 64-65 [2] Kowalski G. Suppression of ring artifacts in CT fan-beam scanners[J]. IEEE Trans on Nucl Sci, 1978, 25(5):1111-1116 [3] Davis G R, Elliott J C. X-ray microtomography scanner using time-delay integration for elimination of ring artifacts in the reconstructed image[J]. Nuclear Instruments & Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 394(1/2):157-162 [4] Raven C. Numerical removal of ring artifacts in microtomography[J]. Review of Scientific Instruments,1998,69(8):2978-2980 [5] Rivers M. Tutorial introduction to X-ray computed microtomography data processing . Chicago:University of Chicago, 1998.http://www-fp.mcs.anl.gov/xray-cmt/rivers/tutorial.html [6] Mantani A, Terakawa K. Artifact reduction filtering method for CT images Annual International Conference of the IEEE Engineering in Medicine and Biology-Proceedings.Piscataway,NJ:IEEE,2002,2:1035-1036 [7] Nagarkar V, Guptar T, Klugeman Y. Structured CsI(Tl) scintillator X-ray imaging applications[J]. IEEE Transactions on Nuclear Science,1998,45(3):492-496 [8] 李俊江,路宏年,李保磊.图像增强器像元通道响应不一致性的分析和校正[J].光学技术,2006,32(5):779-781 Li Junjiang, Lu Hongnian,Li Baolei. Analysis and correction of XRII-CCD pixel response nonuniformity[J]. Optical Technique, 2006,32(5):779-781(in Chinese)
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views(4712) PDF downloads(2123) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return