Volume 34 Issue 09
Sep.  2008
Turn off MathJax
Article Contents
Sun Minglei, Shi Jingxin, Dong Dai, et al. Performance analysis and improvement on acutely defocused scenes[J]. Journal of Beijing University of Aeronautics and Astronautics, 2008, 34(09): 1032-1036. (in Chinese)
Citation: Sun Minglei, Shi Jingxin, Dong Dai, et al. Performance analysis and improvement on acutely defocused scenes[J]. Journal of Beijing University of Aeronautics and Astronautics, 2008, 34(09): 1032-1036. (in Chinese)

Performance analysis and improvement on acutely defocused scenes

  • Received Date: 27 Aug 2007
  • Publish Date: 30 Sep 2008
  • Some classic focusing measures such as gradient function, Brenner function and entropy function, et al, show poor performance in computing high frequency energy in acutely defocused images. Their focusing curves away from the focus show serious nonmonotonicity. The Fourier transform method for image series spectrum analysis was conducted. Three reasons for poor performance in far away focus region were proposed. Firstly, defocused image sequences show strong volatility in power of DC(direct current) component. Secondly, DC component of the image spectrum occupies an overwhelming proportion. Thirdly, the traditional measures have weak ability in filtering DC component of image. According to this, two spatial focusing measures were presented. Experiment results show that performance of focusing curves of acutely defocused images was significantly improved, and high focus resolution can be achieved. This method is particularly important in enhancing reliability of automatic micromanipulation based on microscopic vision.

     

  • loading
  • [1] Geusebroek J M,Cornelissen F,Smeulders A W M,et al.Robust autofocusing in microscopy[J].Cytometry,2000,39:1-9 [2] Santos A,Solorzano C O D,Vaquero J J,et al.Evaluation of autofocus functions in molecular cytogenetic analysis[J].Journal of Microscopy,1997,188(3):264-272 [3] Yeo T,Ong S,Sinniah R.Autofocusing for tissue microscopy[J].Image Vision Comput,1993,11:629-639 [4] Groen F,Young I T,Ligthart G.A comparision of different focus functions for use in autofocus algorighms[J].Cytometry,1985,12:81-91 [5] Vollath D.The influence of the secne parameters and of noise on the behaviour of automatic focusing algorithms[J].J Microsc,1988,151:133-146 [6] Allegro S,Chanel C,Jacot J.Autofocus for automated microassembly under a microscope[J].Image Processing,1996,2:677-680 [7] Brenner J F,Dew B S, Horton J B,et al.An automated microscope for cytologic research[J].Cytometry,1971,24:100-111 [8] Sun Minglei,Zong Guanghua,Bi Shusheng,et al. Research on wavelet based autofocus evaluation in micro-vision[J].Chinese Journal of Aeronautics, 2006, 19(3): 239-246 [9] Tamura H,Mori S,Yamawaki T.Texture features corresponding to visual perception[J].IEEE Trans on System,Man and Cybernetics,1978,8(6):460-473 [10] Yang G,Nelson B J.Wavelet-based autofocusing and unsupervised segmentation of microscopic images Proceedings of the 2003 IEEE/RSJ International Conference on Intelligent Robotics and Systems. Piscataway,NJ:IEEE,2003,3:2143-2148
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views(3028) PDF downloads(874) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return