Fault diagnosis for SHA/EMA redundant system based on bond graph model

doi: 10.13700/j.bh.1001-5965.2018.0150
Funds:

National Natural Science Foundation of China 51275021

More Information
  • Corresponding author: YU Liming, E-mail: yuliming@buaa.edu.cn
  • Received Date: 22 Mar 2018
  • Accepted Date: 23 Nov 2018
  • Publish Date: 20 Apr 2019
  • For the complex fault modes in the redundant system composed of servo-controlled hydraulic actuator (SHA) and electromechanical actuator (EMA), the fault diagnosis method based on bond graph model can be used to diagnose many parameter faults in the system. Firstly, the behavioral model of SHA/EMA redundant system was established, from which the diagnostic bond graph model was transformed according to the causality inversion method, and then the analytical redundancy relation (ARR) was derived to calculate system residuals, and the fault signature matrix (FSM) was created as a basis for fault isolation. Several typical faults were selected for simulation verification. Behavioral model and diagnostic model were coupled to diagnose isolated faults, and fault parameters were estimated through ARR to diagnose inseparable faults. The results show that both isolated and inseparable faults are successfully isolated, and this method is verified to be effective and feasible for fault diagnosis of SHA/EMA redundant system.

     

  • loading
  • [1]
    范殿梁, 付永领, 郭彦青, 等.非相似余度作动系统动态力均衡控制策略[J].北京航空航天大学学报, 2015, 41(2):234-240. http://bhxb.buaa.edu.cn/CN/abstract/abstract13154.shtml

    FAN D L, FU Y L, GUO Y Q, et al.Dynamic force equalization for dissimilar redundant actuator system[J].Journal of Beijing University of Aeronautics and Astronautics, 2015, 41(2):234-240(in Chinese). http://bhxb.buaa.edu.cn/CN/abstract/abstract13154.shtml
    [2]
    王少萍.工程可靠性[M].北京:北京航空航天大学出版社, 2000:103-104.

    WANG S P.Engineering reliability[M].Beijing:Beihang University Press, 2000:103-104(in Chinese).
    [3]
    GAWTHROP P J, BEVAN G P.Bond-graph modeling[J]. IEEE Control Systems, 2007, 27(2):24-45. doi: 10.1109/MCS.2007.338279
    [4]
    AROGETI S A, WANG D, CHANG B L, et al.Fault detection isolation and estimation in a vehicle steering system[J].IEEE Transactions on Industrial Electronics, 2012, 59(12):4810-4820. doi: 10.1109/TIE.2012.2183835
    [5]
    TOUFIGHI M H, SADATI S H, NAJAFI F.Modeling and analysis of a mechatronic actuator system by using bond graph methodology[C]//2007 IEEE Aerospace Conference.Piscataway, NJ: IEEE Press, 2007: 1-8.
    [6]
    徐流建.基于键合图和BP神经网络的并网逆变器故障诊断研究[D].乌鲁木齐: 新疆大学, 2015: 1-2.

    XU L J.Research on grid inverter fault diagnosis based on bond graph and the BP neural network[D].Urumqi: Xinjiang University, 2015: 1-2(in Chinese).
    [7]
    NAWAZ M H, YU L M, LIU H F, et al.Analytical method for fault detection & isolation in electro-hydrostatic actuator using bond graph modeling[C]//International Bhurban Conference on Applied Sciences and Technology.Piscataway, NJ: IEEE Press, 2017: 312-317.
    [8]
    SAMANTARAY A K, MEDJAHER K, BOUAMAMA B O, et al.Diagnostic bond graphs for online fault detection and isolation[J].Simulation Modelling Practice & Theory, 2006, 14(3):237-262. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=e25768c3e32d8f751809ace149bf0fe8
    [9]
    郭丽丽.功率电传混合作动系统体系结构优化分析与设计[D].北京: 北京航空航天大学, 2014.

    GUO L L.Optimization analysis and design on the architecture of power-by-wire hybrid actuation system[D].Beijing: Beihang University, 2014(in Chinese).
    [10]
    张煜东.非相似余度机电液综合作动系统性能分析和优化设计[D].北京: 北京航空航天大学, 2016.

    ZHANG Y D.Performance analysis and optimization design of dissimilar redundant integrated electro-hydraulic actuation system[D].Beijing: Beihang University, 2016(in Chinese).
    [11]
    SAMANTARAY A K, BOUAMAMA B O.Model-based process supervision:A bond graph approach[M].Berlin:Springer, 2008:214-217.
    [12]
    STAROSWIECKI M, COMTET-VARGA G.Analytical redundancy relations for fault detection and isolation in algebraic dynamic systems[J].Automatica, 2001, 37(5):687-699. doi: 10.1016/S0005-1098(01)00005-X
    [13]
    CHINNIAH Y, BURTON R, HABIBI S.Failure monitoring in a high performance hydrostatic actuation system using the extended Kalman filter[J].Mechatronics, 2006, 16(10):643-653. doi: 10.1016/j.mechatronics.2006.04.004
    [14]
    汪宇亮.基于AMESim的工程机械液压系统故障仿真研究[D].武汉: 武汉理工大学, 2012: 47-48.

    WANG Y L.Research on engineering mechanical hydraulic system fault simulation study based on AMESim[D].Wuhan: Wuhan University of Technology, 2012: 47-48(in Chinese).
    [15]
    JIAN F, MARÉ J C, FU Y.Modelling and simulation of flight control electromechanical actuators with special focus on model architecting, multidisciplinary effects and power flows[J].Chinese Journal of Aeronautics, 2017, 30(1):47-65. doi: 10.1016/j.cja.2016.07.006
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(11)  / Tables(2)

    Article Metrics

    Article views(866) PDF downloads(334) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return