Optimization for settings of sensor array in electromagnetic tomography

doi: 10.13700/j.bh.1001-5965.2019.0246
Funds:

National Natural Science Foundation of China 61771041

More Information
  • Corresponding author: MIAO Yu. E-mail: ymiao@bjtu.edu.cn
  • Received Date: 22 May 2019
  • Accepted Date: 19 Aug 2019
  • Publish Date: 20 Feb 2020
  • The settings of the sensor array in electromagnetic tomography (EMT) determine the number of induced voltages, which have an important influence on reconstructed image quality. To study the effect of the settings of coils on the quality of reconstructed images, the number and the position of the sensor array are discussed for optimization. In this paper, the models with different numbers of coils and different contributions are established by using COMSOL Multi-physics; the different algorithms are used to image reconstruction and the quality of the constructed images was compared by correlation coefficient. The simulation shows that the image quality improved by increasing the number of sensors, but when increased to a certain number, the image quality will become worse if the number of the coils continue to increase. In order to increase the measurement data instead of increasing the number of the sensor array, the sensor array is rotated. By comparing the image quality before and after rotation, the result shows that the quality of the reconstructed image is obviously improved after the combination. The simulation results can be a guide for the settings of the sensor array in the design of the EMT system in future work.

     

  • loading
  • [1]
    王化祥, 崔自强, 许燕斌, 等.电学层析成像技术及应用[C]//2009年中国自动化大会暨两化融合高峰会议, 2009: 1-13.

    WANG H X, CUI Z Q, XU Y B, et al.Electrical tomography: State of the art[C]//2009 China Automation Conference and Integration Conference, 2009: 1-13(in Chinese).
    [2]
    YIN W, PEYTON A J.A planar EMT system for the detection of faults on thin metallic plates[J].Measurement Science and Technology, 2006, 17(8):2130-2135. doi: 10.1088/0957-0233/17/8/011
    [3]
    TERZIJA N, YIN W L, GERBETH G, et al.Electromagnetic inspection of a two-phase flow of GaInSn and argon[J].Flow Measurement and Instrumentation, 2011, 22(1):10-16. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=128b3ef0eb657572ee3048b03d530e88
    [4]
    GRIFFITHS H, STEWART W R, GOUGN W.Magnetic induction tomography:A measuring system for biological tissues[J].Annals of the New York Academy of Sciences, 1999, 873(1):335-345. doi: 10.1111-j.1749-6632.1999.tb09481.x/
    [5]
    PEYTON A J, BECK M S, BORGES A R, et al.Development of electromagnetic tomography (EMT) for industrial applications.Part1:Sensor design and instrumentation[C]//1st World Congress on Industrial Process Tomography, 1999:306-312.
    [6]
    ZAKARIA Z, RAHIM R A, SAIFUL M, et al.Advancement in transmitters and sensors for biological tissue imaging in magnetic induction tomography[J].Sensors, 2012, 12:7126-7156. doi: 10.3390/s120607126
    [7]
    BORGES A R, DE OLIVEIRA J E, VELEA J, et al.Development of electromagnetic tomography(EMT) for industrial applications.Part2:Image reconstruction and software framework[C]//1st World Congress on Industrial Process Tomography, 1999:14-17.
    [8]
    PEYTON A J, YU Z Z, LYON G, et al.An overview of electromagnetic inductance tomography:Description of three different systems[J].Measurement Science and Technology, 1993, 7(3):261-271. doi: 10.1088-0957-0233-7-3-006/
    [9]
    LIU Z, LI W, XUE F, et al.Electromagnetic tomography rail defect inspection[J].IEEE Transactions on Magnetics, 2015, 51(10):1-7. http://d.old.wanfangdata.com.cn/NSTLQK/NSTL_QKJJ0235383759/
    [10]
    XIE C G, HUANG S M, HOYLE B S, et al.Electrical capacitance tomography for flow imaging:System model for development of image reconstruction algorithms and design of primary sensor[J].IEEE Proceedings G, 1992, 139(1):89-98. https://ieeexplore.ieee.org/document/125122/
    [11]
    KTISTIS C, ARMITAGE D W, PEYTON A J.Calculation of the forward problem for absolute image reconstruction in MIT[J].Physiological Measurement, 2008, 29:455-464. doi: 10.1088/0967-3334/29/6/S38
    [12]
    XIONG H L, XU L A.Electromagnetic tomography(EMT):Theoretical analysis of the forward problem[J].Applied Mathematics and Mechanics(English Edition), 2000, 21(9):1034-1044. doi: 10.1007/BF02459313
    [13]
    YIN W L, PEYTON A J, STEFANI F, et al.Theoretical and numerical approaches to the forward problem and sensitivity calculation of a novel contactless inductive flow tomography(CIFT)[J].Measurement Science and Technology, 2009, 20(10):105503. doi: 10.1088/0957-0233/20/10/105503
    [14]
    徐凯, 陈广, 尹武良, 等.基于场量提取法的电磁层析成像系统的灵敏度推算[J].传感技术学报, 2011, 24(4):543-547. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=cgjsxb201104015

    XU K, CHEN G, YIN W L, et al.Sensitivity estimation of electromagnetic tomography system based on field volume extraction method[J].Journal of Transduction Technology, 2011, 24(4):543-547(in Chinese). http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=cgjsxb201104015
    [15]
    LIU Z J, BABOUT L, BANASIAK R, et al.Effectiveness of rotatable sensor to improve image accuracy of ECT system[J].Flow Measurement and Instrumentation, 2010, 21(3):219-227. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=4b6354430f4570ab66077a04bb42748f
    [16]
    YANG W Q, PENG L H.Image reconstruction algorithm for electrical capacitance tomography[J].Measurement Science and Technology.2003, 14(1):1-13. doi: 10.1088/0957-0233/14/1/301
    [17]
    LI F, ABASCAL J F P J, DESCO M, et al.Total variation regularization with Split Bregman-based method in magnetic induction tomography using experimental data[J].IEEE Sensors Journal, 2017, 14(1):976-986. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=a1f1434dca830f09f6350860fe2908ca
    [18]
    LIU L, SHAO F Q.Modified conjugate gradient algorithm for image reconstruction of electromagnetic tomography[J].Chinese Journal of Scientific Instrument, 2010, 31(3):655-658. http://en.cnki.com.cn/Article_en/CJFDTOTAL-YQXB201003032.htm
    [19]
    XIE C G, HUANG S M, LENN C P, et al.Experimental evaluation of capacitance tomographic flow imaging systems using physical models[J].IEE Proceedings Circuits Devices and Systems, 1994, 141(5):357-368. doi: 10.1049/ip-cds:19941152
    [20]
    陈晓艳, 常晓敏.基于评价指标的EIT算法参数选择方法研究[J].天津科技大学学报, 2016, 31(6):64-68. http://d.old.wanfangdata.com.cn/Periodical/tjqgyxyxb201606012

    CHEN X Y, CHANG X M.Study on parameter selection method of EIT algorithm based on evaluation index[J].Journal of Tianjin University of Science and Technology, 2016, 31(6):64-68(in Chinese). http://d.old.wanfangdata.com.cn/Periodical/tjqgyxyxb201606012
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(11)  / Tables(4)

    Article Metrics

    Article views(712) PDF downloads(161) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return