Volume 31 Issue 06
Jun.  2005
Turn off MathJax
Article Contents
Zheng Dezhi, Fan Shangchun, Xing Weiweiet al. Novel closed loop system and output signal processing of digital Coriolis mass flowmeter[J]. Journal of Beijing University of Aeronautics and Astronautics, 2005, 31(06): 623-626. (in Chinese)
Citation: Zheng Dezhi, Fan Shangchun, Xing Weiweiet al. Novel closed loop system and output signal processing of digital Coriolis mass flowmeter[J]. Journal of Beijing University of Aeronautics and Astronautics, 2005, 31(06): 623-626. (in Chinese)

Novel closed loop system and output signal processing of digital Coriolis mass flowmeter

  • Received Date: 07 Jan 2004
  • Publish Date: 30 Jun 2005
  • In the processing of designing Coriolis mass flow measurement system, the novel digital method for processing the signals and calculating the results was introduced. The high performance parallel analog to digital converter (A/D) was utilized to sample the whole signals of the sensor. The sample data were deeply analyzed and processed by the high performance floating point DSP (digital signal processor). The classical signal processing method was used to filter the sample data and calculate the phase difference of the two signals, and that the mass flow and density of the liquid were calculated. The system was controlled and the output results were displayed and transferred by the single chip processor and the FPGA (field programmable gate array). Furthermore, the novel digital closed loop was brought forward in the closed loop resonant circuit, the digital circuits and digital signal processing methods were used to realize the traditional AGC (auto gain control) in the closed loop circuit. The experimental results show that the offset and the precision of the system are improved.

     

  • loading
  • [1] 樊尚春. 科里奥利直接质量流量计[J]. 中国学术期刊文摘,1999,5(12):1552~1554 Fan Shangchun. Direct Coriolis mass flowmeter[J]. Chinese Science Abstracts, 1999,5(12):1552~1554(in Chinese) [2] Ilic D, Butorac J. Use of precise digital voltmeters for phase measurements[J]. IEEE Transactions on Instrumentation and Measurements, 2001,50(2):449~452 [3] Henry M. Self-validating digital Coriolis mass flowmeter[J]. Computing & Control Engineering Journal, 2000.219~227 [4] 樊尚春,周浩敏. 信号与测试技术[M]. 北京:北京航空航天大学出版社,2002.186~188 Fan Shangchun, Zhou Haomin. Signal and measurement technology[M]. Beijing:Beijing University of Aeronautics and Astronautics Press, 2002. 186~188(in Chinese) [5] 宋明刚,樊尚春. 非线性对Coriolis质量流量测量管振动特性影响的理论研究[J]. 仪器仪表学报,2002,23(4):361~365 Song Minggang, Fan Shangchun. Analytical study of the influence of nonlinearity on vibration of tube of Coriolis mass flowmeter[J]. Chinese Journal of Scientific Instrument, 2002,23(4):361~365(in Chinese)
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views(488) PDF downloads(1116) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return