Volume 39 Issue 3
Mar.  2013
Turn off MathJax
Article Contents
Liao Pingping, Cai Maolin. High accuracy method of ultrasonic gas leak direction detection based on time delay estimation[J]. Journal of Beijing University of Aeronautics and Astronautics, 2013, 39(3): 391-395. (in Chinese)
Citation: Liao Pingping, Cai Maolin. High accuracy method of ultrasonic gas leak direction detection based on time delay estimation[J]. Journal of Beijing University of Aeronautics and Astronautics, 2013, 39(3): 391-395. (in Chinese)

High accuracy method of ultrasonic gas leak direction detection based on time delay estimation

  • Received Date: 10 Feb 2012
  • Publish Date: 31 Mar 2013
  • In order to solve the low accuracy problem in current gas leak detection, a new ultrasonic leak detection method based on time delay estimation (TDE) was proposed.Three ultrasonic sensors arranged in an equilateral triangle and received the ultrasound generated by a gas leak and the leak direction can be determined according to time delays between the outputs of every two sensors.A TDE algorithm based on cubic spline interpolation was adopted to overcome the accuracy limit caused by sampling interval.For each kernel window length, delay estimates of 100 sets of experimental data were obtained and their mean squared errors (MSE) were calculated.Comparison between MSE of experimental data and Cramér-Rao lower bound showed that their changing tendency was accordant.Influences of MSE, the space between sensors and the distance between leak and sensor on direction accuracy were analyzed.Results show that the direction error increases with MSE, decreases with the space between sensors, and increases with distance between leak and sensor.The direction detection accuracy is improved by 7~10 times compared with detection method with single ultrasonic sensor.

     

  • loading
  • [1] 蔡茂林,香川利春.气动系统的能量消耗评价体系及能量损失分析[J].机械工程学报,2007,43(9):69-74 Cai Maolin, Kagawa T.Energy consumption assesment and energy loss analysis in pneumatic system [J].Chinese Journal of Mechanical Engineering, 2007, 43(9):69-74(in Chinese) [2] Saidur R, Rahim N A, Hasanuzzaman M.A review on compressed-air energy use and energy savings [J].Renewable and Sustainable Energy Reviews, 2010,14(4):1135-1153 [3] Goodman M, Zeno J R, Mabbs L.Ultrasonic leak detecting apparatus: United States, 5955670[P].1999-09-21 [4] Izikoff M, Stumpf M, Samson H.System and method for leak detection: United States, 2010/0039271A1 [P].2010-3-18 [5] Edwards P A, Bruck F, Hennessy J.Sonic leak testing on ink delivery systems and ink jet heads: United States, 7770999B2 [P].2010-08-10 [6] Crespo R J.Evaluation of energy usage in the chemical industry and effective measures to reduce energy losses [D].Starkville: Mississippi State University, 2009 [7] Liao Pingping, Cai Maolin.Study on compressed air leak detection using ultrasonic detection technology and instrument [C]//Proceedings of 6th IEEE Conference on Industrial Electronics and Applications.Beijing, China: IEEE, 2011:1690-1693 [8] 冯若, 姚锦钟,关立勋, 等.超声手册[M].南京: 南京大学出版社, 1999: 254-260 Feng Ruo, Yao Jinzhong, Guan Lixun, et al.Ultrasonics handbook [M].Nanjing : Nanjing University Press, 1999: 254-260(in Chinese) [9] 植木孝.超音波式ガス漏洩検出器[J].センサ技術,1987,7(11):18-20 [10] Cespedes I, Huang Y, Ophir J, et al.Methods for estimation of subsample time delays of digitized echo signals [J].Ultrasonic Imaging, 1995,17(2):142-171 [11] Lai Xiaoming, Torp H.Interpolation methods for time-delay estimation using cross-correlation method for blood velocity measurement [J].IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1999, 46(2): 277-290 [12] Viola F, Walker W F.A spline-based algorithm for continuous time-delay estimation using sampled data [J].IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2005, 52(1): 80-93 [13] Carter G C.Coherence and time delay estimation [J].Proceedings of the IEEE, 1987, 75(2):236-255 [14] Walker W F, Trahey G E.A fundamental limit on delay estimation using partially correlated speckle signals [J].IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control,1995, 42(2): 301-308 [15] Viola F, Walker W F.A comparison of the performance of time-delay estimators in medical ultrasound [J].IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2003, 50(4): 392-401
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views(1715) PDF downloads(699) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return