Volume 33 Issue 10
Oct.  2007
Turn off MathJax
Article Contents
Yang Min, Sun Cuili, Li Baoleiet al. Method for measuring the focal distance of 3D-CT imaging system with high accuracy using image auto-correlation[J]. Journal of Beijing University of Aeronautics and Astronautics, 2007, 33(10): 1216-1219. (in Chinese)
Citation: Yang Min, Sun Cuili, Li Baoleiet al. Method for measuring the focal distance of 3D-CT imaging system with high accuracy using image auto-correlation[J]. Journal of Beijing University of Aeronautics and Astronautics, 2007, 33(10): 1216-1219. (in Chinese)

Method for measuring the focal distance of 3D-CT imaging system with high accuracy using image auto-correlation

  • Received Date: 20 Oct 2006
  • Publish Date: 31 Oct 2007
  • In the three dimensional computed tomography imaging system, it is impossible to measure the X-ray focus to object-rotating-axis distance (FOD) by direct means, so how to obtain the value of FOD with simple and feasible method is an involved engineering problem. Through acquiring the digital radiography(DR) images of the double-circled object at two imaging positions, the auto-correlation operation was executed, so as to get distance of the two circles- projection center. Then through solving equations, the value of FOD was finally obtained. Experiment results prove that the accuracy of this method can satisfy the requirements of the practical scanning system. This testing method is also easy to realize and of high anti-noise ability. Furthermore, it can be realized automatically by software.

     

  • loading
  • [1] Feldcamp L A, Davis L C, Kress J W. Practical cone-beam algorithm[J]. J Opt Soc Am Al,1984:612-619 [2] 倪建平,李政,白宏涛,等. 微焦点X 射线成像系统扫描参数测量及投影图像校正研究[J]. 核电子学与探测技术,2001,21(3):165-168 Ni Jianping, Li Zheng, Bai Hongtao,et al. Scanning parameter measure ment and project correction for microfocus X-ray imaging system[J]. Nuclear Electronics & Detection Technology, 2001, 21(3):165-168(in Chinese) [3] 杨民. 基于面阵探测器的多模式工业CT技术研究 .北京:北京航空航天大学机械及自动化学院,2004 Yang Min. Research on multi-mode industrial computed tomography based on flat panel detector .Beijing: School of Mechanical Engineering and Automation, Beijing University of Aeronautics and Astronautics,2004(in Chinese) [4] Jiang Hangyi. Techniques to improve the accuracy and to reduce the variance in noise power spectrum measurement[J]. IEEE Transactions on Biomedical Engineering, 2002, 49(11): 1270-1278 [5] Van Metter Richard, Yorkston John. Factors influencing image quality in digital radiographic system[J]. Proc SPIE Int Soc Opt Eng, 2001, 4320: 244-255
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views(3486) PDF downloads(1078) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return