Volume 33 Issue 02
Feb.  2007
Turn off MathJax
Article Contents
Wei Dongbo, Fu Jian, Li Bing, et al. Design technique based on CDD function for industrial CT system[J]. Journal of Beijing University of Aeronautics and Astronautics, 2007, 33(02): 214-218. (in Chinese)
Citation: Wei Dongbo, Fu Jian, Li Bing, et al. Design technique based on CDD function for industrial CT system[J]. Journal of Beijing University of Aeronautics and Astronautics, 2007, 33(02): 214-218. (in Chinese)

Design technique based on CDD function for industrial CT system

  • Received Date: 30 Sep 2006
  • Publish Date: 28 Feb 2007
  • Industrial computed tomography(ICT) is an advanced, non-contact and non-destructive testing method. It is complicated, non-universal and expe ns ive. It is necessary to make the custom development to reduce the risk and the c ost. A kind of design technique frame based on the contrast-detail-dose(CDD) fu nction was proposed for the development of ICT system. According to this frame, t he design method for fan-beam 3rd generation two dimensional ICT(2D-ICT) was d ed uced and the corresponding software platform was implemented which is consisted of three parts. They are the computer aided design(CAD) part based on the CDD func tion, the simulation part and the performance evaluation part. The initial desig n parameters firstly entered the CAD part. They secondly entered the simulation part if they passed the CAD check. The simulation results were finally evaluated by the evaluation part. The validity of the proposed method was proved by the computer simulation and the example of the engineering development.

     

  • loading
  • [1] Hammersberg P. A theoretical model for determination of the optimal irradiation conditions for computerized tomography[J]. Insight, 1 995, 37(12):978-985 [2] Hammersberg P, Mangard M. Optimal computerized tomography performance Proceedings BB 67CD. Berlin:DGZfp, 1999:31-43 [3] Mangard M, Hammersberg P. Optimized detail detectability in computerized tomography[J]. Journal of X-ray Science and Technology,1998,8(1):51-73 [4] E1672-95,Standard guide for computed tomography system selection[S] [5] Cohen G,Dibicanca F A. The use of contrast-detail-dose evaluation of i mage quality in a computed tomographic scanner[J]. J Comput Assist Tomogr,197 9,3:189-195 [6] Kensuke S,Rideki K,Shinji Y. Theoretical prediction of X-ray CT image quality using contrast-detail diagrams[J]. IEEE Trans on Nucl Sci,1982,NS- 29:2115-2121 [7] Cohen G,Wagner L K,Amtey S R. Contrast-detail-dose and dose efficienc y analysis of a scanning digital and a screen-film-grid radiographic system . Med Phy,1981,8(3):358-367 [8] 傅健. X射线三代工业CT工程关键技术研究 . 北京:北京航空航天大学机械工程及自动化学院,2004 Fu Jian. Research on engineering techniques for X-ray generation III industr ial CT and its application . Beijing:School of Mechanical Engineering and A utomation, Beijing University of Aeronautics & Astronautics, 2004(in Chinese) [9] E1441-00,Standard guide for computed tomography(CT) imaging[S] . [10] Gore J C,Tofts P S. Statistical limitations in computed tomogra phy[J]. Phys Med Biol,1978,23:1176-1182 [11] E1570-93,Standard practice for computed tomography(CT) examination
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views(31162) PDF downloads(2822) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return