Citation: | ZHONG Wanli, WANG Wei, LIN Jiedong, et al. Experimental analysis on infrared temperature measurement of flue gas covering surface[J]. Journal of Beijing University of Aeronautics and Astronautics, 2017, 43(2): 218-223. doi: 10.13700/j.bh.1001-5965.2015.0795(in Chinese) |
Radiative participant flue gas has important influence on the infrared surface temperature measurement of flue gas covering surface. According to the characteristic of the sample temperature distribution measured by an infrared CCD camera, a simplified one-dimensional model of infrared surface temperature measurement is established. Based on the simplified model, the detected infrared temperatures at different thickness of flue gas and surface temperature of sample are analyzed using source multi-flux method. Finally, a muffle furnace is used to heat the measured surface, and a vibrating screen is used to simulate flue gas covering environment. An infrared temperature measurement system is built for flue gas covering surface. The analytical model of source multi-flux is verified by the experiments, and the measured temperature by the experimental has a good agreement with the predicted temperature by the analytical model. The idea of modification for the infrared temperature measurement by inverse method is proposed.
[1] |
段远源, 刘东, 杨震.锅炉过热器炉内壁面温度红外测量信号的波动特征及数据处理方法[J].中国电机工程学报, 2012, 32(8):1-5. http://www.cnki.com.cn/Article/CJFDTOTAL-ZGDC201208002.htm
DUAN Y Y, LIU D, YANG Z.Fluctuation characteristics and data processing method of infrared measurement signal of superheaters inner wall temperature in utility boiler[J].Proceedings of the CSEE, 2012, 32(8):1-5(in Chinese). http://www.cnki.com.cn/Article/CJFDTOTAL-ZGDC201208002.htm
|
[2] |
袁益超, 陈之航, 王国华, 等.大容量电站锅炉汽温问题及过热器与再热器超温爆管原因的分析[J].动力工程, 1994, 14(6):21-28. http://www.cnki.com.cn/Article/CJFDTOTAL-DONG406.004.htm
YUAN Y C, CHEN Z H, WANG G H, et al.The problem of steam temperature in large-capacity power plant boiler and analysis of the tube explosion of superheater and reheater[J].Power Engineering, 1994, 14(6):21-28(in Chinese). http://www.cnki.com.cn/Article/CJFDTOTAL-DONG406.004.htm
|
[3] |
ALWAALY A A Y, PAUL M C, DOBSON P S.Effects of thermocouple electrical insulation on the measurement of surface temperature[J].Applied Thermal Engineering, 2015, 89:421-431. doi: 10.1016/j.applthermaleng.2015.06.020
|
[4] |
CHILDS P R N, GREENWOOD J R, LONG C A.Review of temperature measurement[J].Review of Scientific Instruments, 2000, 71(8):2959-2978. doi: 10.1063/1.1305516
|
[5] |
DUDAS J.Characterization and avoidance of in-field defects in solid-state image sensors[D].Burnaby:Simon Fraser University, 2008.
|
[6] |
JONES T E, URQUHART M E, BADDELEY C J.An investigation of the influence of temperature on the adsorption of the chiral modifier, (S)-glutamic acid, on Ni {111}[J].Surface Science, 2005, 587(1):69-77. http://adsabs.harvard.edu/abs/2005SurSc.587...69J
|
[7] |
LIU W, JIA X H, JIA Z Y, et al.Fast dimensional measurement method and experiment of the forgings under high temperature[J].Journal of Materials Processing Technology, 2011, 211(2):237-244. doi: 10.1016/j.jmatprotec.2010.09.015
|
[8] |
MIYAMOTO T, ISHIZAWA H, NITTA Y, et al.Evaluation of heat transfer characteristics of textile goods by infrared image measurement method[J].Journal of Textile Engineering, 2006, 52(1):37-41. doi: 10.4188/jte.52.37
|
[9] |
TANK V, DIETL H.Multispectral infrared pyrometer for temperature measurement with automatic correction of the influence of emissivity[J].Infrared Physics, 1990, 30(4):331-342. doi: 10.1016/0020-0891(90)90049-2
|
[10] |
李云红, 孙晓刚, 原桂彬.红外热像仪精确测温技术[J].光学精密工程, 2007, 15(9):1336-1341. http://www.cnki.com.cn/Article/CJFDTOTAL-GXJM200709008.htm
LI Y H, SUN X G, YUAN G B.Accurate measuring temperature with infrared thermal imager[J].Optics and Precision Engineering, 2007, 15(9):1336-1341(in Chinese). http://www.cnki.com.cn/Article/CJFDTOTAL-GXJM200709008.htm
|
[11] |
LIU L H, LI B X.Inverse radiation problem of axisymmetric turbulent sooting free flame[J].Journal of Quantitative Spectroscopy and Radiative Transfer, 2002, 75(4):481-491. doi: 10.1016/S0022-4073(02)00032-8
|
[12] |
LIU L H, TAN H P, LI B X.Influence of turbulent fluctuation on reconstruction of temperature profile in axisymmetric free flames[J].Journal of Quantitative Spectroscopy and Radiative Transfer, 2002, 73(6):641-648. doi: 10.1016/S0022-4073(01)00183-2
|
[13] |
YANG Z, ZHANG S C, YANG L.Calculation of infrared temperature measurement on non-Lambertian objects[J].Spectroscopy and Spectral Analysis, 2010, 30(8):2093-2097. https://www.researchgate.net/publication/47402706_Calculation_of_Infrared_Temperature_Measurement_on_Non-Lambertian_Objects
|
[14] |
齐宏, 牛春洋, 张丽琴, 等.高温半透明介质折射率及吸收系数反演测量装置及方法:201510607276.0[P].2015-12-30.
QI H, NIU C Y, ZHANG L Q, et al.A kind of method and device for measurement of refractive index and absorption coefficient of high temperature semitransparent media:201510607276.0[P].2015-12-30(in Chinese).
|
[15] |
NIU C Y, QI H, HUANG X, et al.Simultaneous reconstruction of temperature distribution and radiative properties in participating media using a hybrid LSQR-PSO algorithm[J].Chinese Physics B, 2015, 24(11):114401. doi: 10.1088/1674-1056/24/11/114401
|
[16] |
王伟, 钟万里, 林介东, 等.电站锅炉高温烟气对壁面红外测温的影响[J].仪表技术与传感器, 2016(1):87-89. http://www.cnki.com.cn/Article/CJFDTOTAL-YBJS201601027.htm
WANG W, ZHONG W L, LIN J D, et al.Effect of high temperature boiler flue gas on infrared surface temperature measurement[J].Instrument Technique and Sensor, 2016(1):87-89(in Chinese). http://www.cnki.com.cn/Article/CJFDTOTAL-YBJS201601027.htm
|