留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码

超声波流量测量中流速计算方法的对比

于洋 宗光华 丁凤林

于洋, 宗光华, 丁凤林等 . 超声波流量测量中流速计算方法的对比[J]. 北京航空航天大学学报, 2013, (1): 37-41.
引用本文: 于洋, 宗光华, 丁凤林等 . 超声波流量测量中流速计算方法的对比[J]. 北京航空航天大学学报, 2013, (1): 37-41.
Yu Yang, Zong Guanghua, Ding Fenglinet al. Comparison of flow rate calculation method for ultrasonic flow measurement[J]. Journal of Beijing University of Aeronautics and Astronautics, 2013, (1): 37-41. (in Chinese)
Citation: Yu Yang, Zong Guanghua, Ding Fenglinet al. Comparison of flow rate calculation method for ultrasonic flow measurement[J]. Journal of Beijing University of Aeronautics and Astronautics, 2013, (1): 37-41. (in Chinese)

超声波流量测量中流速计算方法的对比

详细信息
  • 中图分类号: TH 814

Comparison of flow rate calculation method for ultrasonic flow measurement

  • 摘要: 超声波流量计(UFM,Ultrasonic Flow Meter)通过测量管路中顺流和逆流方向的超声波传播时间变化计算流速,因此超声波传播时间的准确测量对流量计的精度影响至关重要.对超声波流量计的测量方法进行研究,从环境温度的变化、时间测量的准确性、不确定度的计算3个方面,对比超声波传播时间差法和频率差法对流量测量精度的影响.通过超声波流量测量实验,验证了在流量计未校准的情况下,与频率差法相比,时间差法的测量精度更高,且其校准系数曲线的线性度更好,校准后可在全流量范围内获得更高的测量精度.

     

  • [1] Lynnworth L C,Liu Y.Ultrasonic flowmeters:half-century progress report,1955—2005[J].Ultrasonics,2006,44(Supplement):e1371-e1378
    [2] Mandard E,Kouame D,Battault R,et al.Methodology for developing a high-precision ultrasound flow meter and fluid velocity profile reconstruction[J].IEEE Transactions on Ultrasonics,Ferroelectrics and Frequency Control,2008,55(1):161-171
    [3] Lysak P D,Jenkins D M,Capone D E,et al.Analytical model of an ultrasonic cross-correlation flow meter,part 1:stochastic modeling of turbulence[J].Flow Measurement and Instrumentation,2008,19(1):1-7
    [4] Lysak P D,Jenkins D M,Capone D E,et al.Analytical model of an ultrasonic cross-correlation flow meter,part 2:application[J].Flow Measurement and Instrumentation,2008,19(1):41-46
    [5] Calzolai M,Capineri L,Fort A,et al.A 3-D PW ultrasonic Doppler flowmeter:theory and experimental characterization[J].IEEE Transactions on Ultrasonics,Ferroelectrics and Frequency Control,1999,46(1):108-113
    [6] 贺胜,彭黎辉,仲里敏.基于CFD的超声波流量计最优声道位置研究[J].仪器仪表学报,2009,30(4):854-856
    He Sheng,Peng Lihui,Zhong Limin.Computational fluid dynamics based sound path optimization for ultrasonic flow meter[J].Chinese Journal of Scientific Instrument,2009,30(4):854-856(in Chinese)
    [7] Yang B,Cao L,Luo Y.High-speed and precise measurement for ultrasonic liquid flow metering based on a single FPGA//Poceedings of the 2009 IEEE Intrumentation and Measurement Technology Conference.Singapore:IEEE,2009:309-312
    [8] Yu Y,Zong G H.Design and simulation of an ultrasonic flow meter for thin pipe//Poceedings of the 2011 IEEE/ASME International Conference on Mechatronics and Automation.Beijing:IEEE,2011:1115-1119
  • 加载中
计量
  • 文章访问数:  2152
  • HTML全文浏览量:  313
  • PDF下载量:  1051
  • 被引次数: 0
出版历程
  • 收稿日期:  2011-10-21
  • 网络出版日期:  2013-01-31

目录

    /

    返回文章
    返回
    常见问答