Comparison of flow rate calculation method for ultrasonic flow measurement
-
摘要: 超声波流量计(UFM,Ultrasonic Flow Meter)通过测量管路中顺流和逆流方向的超声波传播时间变化计算流速,因此超声波传播时间的准确测量对流量计的精度影响至关重要.对超声波流量计的测量方法进行研究,从环境温度的变化、时间测量的准确性、不确定度的计算3个方面,对比超声波传播时间差法和频率差法对流量测量精度的影响.通过超声波流量测量实验,验证了在流量计未校准的情况下,与频率差法相比,时间差法的测量精度更高,且其校准系数曲线的线性度更好,校准后可在全流量范围内获得更高的测量精度.Abstract: Ultrasonic flow meter (UFM) calculates the flow rate, by measuring the difference of ultrasound transit time between the upstream direction and downstream direction. For the purpose of accurate flow measurement, transit time difference method and frequency difference method were compared from three aspects: change of environment temperature, accuracy of time measurement, and uncertainty calculation. Ultrasonic flow measurement experiment shows, when the flow meter is not calibrated, compared with frequency difference method, transit time difference method can achieve better accuracy. The calibrated factor for the transit time difference method is more linear, so better accuracy is achieved for full flow range measurement.
-
[1] Lynnworth L C,Liu Y.Ultrasonic flowmeters:half-century progress report,1955—2005[J].Ultrasonics,2006,44(Supplement):e1371-e1378 [2] Mandard E,Kouame D,Battault R,et al.Methodology for developing a high-precision ultrasound flow meter and fluid velocity profile reconstruction[J].IEEE Transactions on Ultrasonics,Ferroelectrics and Frequency Control,2008,55(1):161-171 [3] Lysak P D,Jenkins D M,Capone D E,et al.Analytical model of an ultrasonic cross-correlation flow meter,part 1:stochastic modeling of turbulence[J].Flow Measurement and Instrumentation,2008,19(1):1-7 [4] Lysak P D,Jenkins D M,Capone D E,et al.Analytical model of an ultrasonic cross-correlation flow meter,part 2:application[J].Flow Measurement and Instrumentation,2008,19(1):41-46 [5] Calzolai M,Capineri L,Fort A,et al.A 3-D PW ultrasonic Doppler flowmeter:theory and experimental characterization[J].IEEE Transactions on Ultrasonics,Ferroelectrics and Frequency Control,1999,46(1):108-113 [6] 贺胜,彭黎辉,仲里敏.基于CFD的超声波流量计最优声道位置研究[J].仪器仪表学报,2009,30(4):854-856
He Sheng,Peng Lihui,Zhong Limin.Computational fluid dynamics based sound path optimization for ultrasonic flow meter[J].Chinese Journal of Scientific Instrument,2009,30(4):854-856(in Chinese)[7] Yang B,Cao L,Luo Y.High-speed and precise measurement for ultrasonic liquid flow metering based on a single FPGA//Poceedings of the 2009 IEEE Intrumentation and Measurement Technology Conference.Singapore:IEEE,2009:309-312 [8] Yu Y,Zong G H.Design and simulation of an ultrasonic flow meter for thin pipe//Poceedings of the 2011 IEEE/ASME International Conference on Mechatronics and Automation.Beijing:IEEE,2011:1115-1119
点击查看大图
计量
- 文章访问数: 2164
- HTML全文浏览量: 313
- PDF下载量: 1052
- 被引次数: 0