摘要: 为研究飞机客舱设计对防火性能的影响,首次提出火灾疏散安全指数(FESI) 的概念.利用PyroSim及Pathfinder仿真软件对飞机客舱的火灾场景和疏散过程进行模拟,确定不同客舱内表面积、出口宽度和高度及搭载人数下出口的FESI,分析以上设计因素对客舱火灾疏散能力的影响.使用BP神经网络算法确定几种窄体飞机在确保火灾疏散安全情况下的最大搭载人数.并以B737-800飞机为例对其疏散方案进行优化,模拟结果表明:客舱的内部表面积、舱门尺寸及座位数都是显著影响客舱防火性能的设计因素,典型布置下的B737-800飞机最大承载人数为154人,在疏散方案优化后可增加至175人.所提出的FESI不仅可对现有飞机的防火性能进行评估,优化客舱布局及人员疏散方案,还可为国产大型飞机客舱防火设计提供依据,同时为其他领域的消防研究提供参考.
-
关键词:
- 飞机客舱 /
- 火灾 /
- 疏散 /
- 火灾疏散安全指数(FESI) /
- 防火设计
Abstract: In order to study the influence of aircraft cabin design on fire protection performance, a concept of fire evacuation safety index (FESI) was firstly presented. The fire scenario and evacuation procedures in aircraft cabin were simulated via simulation software PyroSim and Pathfinder. FESI at different exits were determined under the scenarios of different internal surface area of cabin, width and height of the exit and population. An analysis was conducted to study the influence of such design factors to cabin fire evacuation performance. The maximum populations of several narrow-body aircrafts were determined using back-propagation (BP) neural network in case to ensure the safe evacuation. And an optimized evacuation program was proposed for B737 aircraft. The results reveal that internal surface area of cabin, width and height of the exits and numbers of seats are the design factors that significantly impact cabin fire protection performance. The maximum population of B737-800 under typical layout is 154. However, it may increase to 175 after optimizing to the evacuation program. The proposed concept of FESI not only performs an assessment for the existing aircrafts against fire protection performance and an optimization for cabin layout and evacuation program, but also provides a basis for fire protection design of domestic large aircraft cabin. In addition, it can also provide a reference for other areas of fire research.-
Key words:
- aircraft cabin /
- fire /
- evacuation /
- fire evacuation safety index (FESI) /
- fire protection design
-
[1] Brown L J Jr. Cabin hazards from a large external fuel fire adjacent to an aircraft fuselage, FAA-RD-79-65[R].Washington, D.C.: Federal Aviation Administration, 1979. [2] Hill R G, Johnson G R, Sarkos C P.Postcrash fuel fire hazard measurements in a wide-body aircraft cabin, FAA-NA-79 42[R].Washington, D.C.: Federal Aviation Administration, 1979. [3] Eklund T I, Sarkos C P.The thermal impact of external pool fires on aircraft fuselages[J].Journal of Fire and Flammability, 1980, 11(3): 231-240. [4] Sarkos C P. Application of full-scale fire tests to characterize and improve the aircraft postcrash fire environment[J].Toxicology, 1996, 115(1): 79-87. [5] Wang Z Z, Jia F C, Galea E R, et al.Computational fluid dynamics simulation of a post-crash aircraft fire test[J].Journal of Aircraft, 2012, 50(1): 164-175. [6] Galea E R.Proposed methodology for the use of computer simulation to enhance aircraft evacuation certification[J].Journal of Aircraft, 2006, 43(5): 1405-1413. [7] Sharma S.Multi-agent modeling and simulation of human behavior in aircraft evacuations transactions on aerospace and electronic systems[J].Aerospace and Electronic Systems, 2008, 23(11): 1477-1488. [8] 张炜, 刘泽奇, 马智. 飞机乘员应急撤离可视化仿真方法研究[J].航空工程进展, 2010, 1(4): 347-351.Zhang W, Liu Z Q, Ma Z.Study on visualization simulation of aircraft emergency evacuation[J].Advances in Aeronautical Science and Engineering, 2010, 1(4): 347-351(in Chinese). [9] 张青松, 戚瀚鹏, 纪欢乐.基于FDS的飞机客舱火灾仿真环境设计[J].计算机工程与设计, 2014, 35(3): 995-998. Zhang Q S, Qi H P, Ji H L.A design of aircraft cabin in fire simulation environment based on FDS[J].Computer Engineering and Design, 2014, 35(3): 995-998(in Chinese). [10] 张青松, 戚瀚鹏, 杨彩红, 等.飞机客舱性能化防火设计方法研究[J].科学技术与工程, 2014, 14(28): 311-315.Zhang Q S, Qi H P, Yang C H, et al.Study on performance-based fire protection design method for aircraft cabin[J].Science Technology and Engineering, 2014, 14: (28): 311-315(in Chinese). [11] Zhang Q S, Qi H P, Zhao G M, et al.Performance simulation of evacuation procedures in post-crash aircraft fires[J].Journal of Aircraft, 2014, 51(3): 945-955. [12] Capote J A, Alvear D, Abreu O, et al.Analysis of evacuation procedures in high speed trains fires[J].Fire Safety Journal, 2012, 49: 35-46. [13] CCAR-25-R4运输类飞机适航标准[S].北京: 中国民用航空总局, 2011. CCAR-25-R4.Airworthiness standards for transport category airplanes[S].Beijing: Civil Aviation Administration of China, 2011(in Chinese). [14] Poon L S, Beck V R.EvacSim: A simulation model of occupants with behavioural attributes in emergency evacuation of high-rise buildings[C]//Proceedings of the 4th International Symposium of Fire Safety Science.Ottawa: IAFSS Digital Archive, 1994: 681-692. [15] Barnett C R. BFD curve: A new empirical model for fire compartment temperatures[J].Fire Safety Journal, 2002, 37(5): 437-463.
点击查看大图
计量
- 文章访问数: 881
- HTML全文浏览量: 84
- PDF下载量: 626
- 被引次数: 0