Kinematics modeling and simulation of seed implantation robot for prostate tumors
-
摘要: 基于测量的人体前列腺会阴部操作空间和手术过程量化分析,研究了一种3-PCR并联式前列腺癌粒子植入机器人。对于这种对称少自由度并联机构作为位置调整机构,其运动学特性需要深入研究。采用封闭矢量法和Beout消元法建立3-PCR并联机构运动学正、逆运动学方程,通过数值计算验证了正、反解模型的正确性。利用MATLAB进行p点为空间旋量曲线时的运动学仿真,仿真结果表明机构具有较好的运动稳定性,便于实时控制。通过极限边界搜索法求解了该机构姿态为α=β=γ=0°下的工作空间,x=0时的YOZ工作空间截面为15 674 mm2能满足临床手术的要求。Abstract: We developed a 3-PCR parallel-chain type of seed implantation robot for prostate tumors, based on measurement workspace in the perineum of prostate and quantitative analysis of the surgery procedure. For this kind of symmetry less degrees of freedom of parallel-chain mechanisms as position adjustment device, the kinematics characteristics need further research. The forward and reverse kinematics equations of 3-PCR parallel-chain mechanisms were established by the closed vector method and Bezout elimination, and forward and reverse model was verified by numerical calculation to be correct. The kinematics simulation was performed under the helical cure in space with point p by MATLAB software, and simulation results provide evidence that this parallel-chain mechanism has better movement stability and is convenient for real-time control. The limit boundary searching method was used to solve the workspace of this mechanism under the posture with α=β=γ=0°, and workspace with YOZ section was 15 674 mm2 under x =0, which also meets the requirements of clinical surgery.
-
Key words:
- prostate cancer /
- seed implantation robot /
- parallel-chain mechanisms /
- kinematics modeling /
- workspace
-
[1] LIAO A Y, WANG J J,WANG J D,et al.Relative biological effectiveness and cell-killing efficacy of continuous low-dose-rate 125I seeds on prostate carcinoma cells in vitro[J].Integrative Cancer Therapies,2010,9(1):59-65. [2] 王俊杰,黄毅,冉维强,等. 125I粒子近距离前列腺癌临床应用[J].中华放射医学与防护,2012,24(2):509-512. WANG J J,HUANG Y,RAN W Q,et al.Clinical application of transperineal 125I-seed implantation guided by ultrasonography in prostate cancer[J].Chinese Journal of Radiological Medicine and Protection,2012,24(2):509-512(in Chinese). [3] ZHANG Y D, PODDER T K,NG W S.Semi-automated needling and seed delivery device for prostate brachytherapy[C]//2006 IEEE/RSJ International Conference on Intelligent Robots and Systems.Piscataway,NJ:IEEE Press,2006:1279-1284. [4] YU Y,PODDER T, ZHANG Y D,et al.Robot-assisted prostate brachytherapy[J].Computer Aided Surgery,2007,12(6):366-370. [5] PODDER T K, NG W S,YU Y.Multi-channel robotic system for prostate brachytherapy[C]//2007 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.Piscataway,NJ:IEEE Press,2007:1233-1236. [6] VAIDA C, PLITEA N,GHERMAN A,et al.Structural analysis and synthesis of parallel robots for brachytherapy[J].New Trends in Medical and Service Robots,2014,16:191-204. [7] JIANG S,GUO J, LIU S,et al.Kinematic analysis of a 5-DOF hybrid-driven MR compatible robot for minimally invasive prostatic interventions[J].Robotica,2012,30(7):1147-1156. [8] 黄真,赵永生, 赵铁石.高等空间机构学[M].北京:高等教育出版社,2006:116-118. HUANG Z,ZHAO Y S,ZHAO T S.Higher spatial mechanism[M].Beijing:Higher Education Press,2006:116-118(in Chinese). [9] 杨廷力. 机器人机构拓扑结构学[M].北京:机械工业出版社,2003:47-48. YANG T L.Topology structure design of robot mechanisms[M].Beijing:China Machine Press,2003:47-48(in Chinese). [10] LUKANIN V. Inverse kinematics,forward kinematics and working space determination of 3DOF parallel manipulator with S-P-R joint structure[J].Periodica Polytechnica,2005,49(1): 39-61. [11] 黄昔光,廖启征, 魏世民,等.一般6-6型平台并联机构位置正解代数消元法[J].机械工程学报,2009,45(1):56-61. HUANG X G,LIAO Q Z,WEI S M,et al.Forward kinematics analysis of the general 6-6 platform parallel mechanism based on algebraic elimination[J].Chinese Journal of Mechanical Engineering, 2009,45(1):56-61(in Chinese). [12] YANG M L, QING S X.Design,analysis and applications of a class of new 3-DOF translational parallel manipulators[M].Vienna: I-Tech Education and Publishing,2005:464-467. [13] 黄田,汪劲松. Stewart并联机器人位置空间解析[J].中国科学(E辑),1998,28(2):136-145. HUANG T,WANG J S.Analysis location spatially of Stewart parallel manipulator[J].Science in China (Series E),1998,28(2): 136-145(in Chinese). [14] 李浩,张玉茹, 王党校.6-RSS并联机构工作空间优化算法对比分析[J].机械工程学报,2010,46(13):61-67. LI H,ZHANG Y R,WANG D X.Comparative analysis of optimization algorithms in workspace optimization of parallel mechanisms[J].Chinese Journal of Mechanical Engineering,2010,46(13):61-67(in Chinese). [15] 杨亚汝,姜露莹, 许小云,等.实时三维超声测量模拟前列腺体积的实验研究[J].临床超声医学,2008,10(1):5-6. YANG Y R,JIANG L Y,XU X Y,et al.Experiment study on imitative measurement of prostate volume with real-time three-dimensional ultrasound[J].Journal of Ultrasound in Clinical Medicine,2008,10(1):5-6(in Chinese).
点击查看大图
计量
- 文章访问数: 765
- HTML全文浏览量: 50
- PDF下载量: 736
- 被引次数: 0