Parallel access leakage flow rate measurement of compressed air
-
摘要: 并联接入式流量测量方法与串联式测量方法相比,接入简单,装卸不需要破坏管道.引入基准流量,根据基准流量发生前后压缩气体的压力变化率可以求解泄漏流量;采用基于非线性微分跟踪器的滤波方法对压力信号滤波,有效消除了噪声的影响.实验结果表明:并连接入式的测量方法测量精度可达到满量程3%,重复精度可达满量程3%,适用于气动节能工业.Abstract: An instantaneous method for measuring leakage flow rate was proposed by employing a standard flow. Measuring equipment was connected to the pipeline, which promised the convenience and non-destruction. Standard flow was used to determine the internal volume of measured equipment. And a nonlinear discrete-time tracking differentiator had been designed to track the differential pressure. Furthermore, an algorithm was formulated to describe, the relationship between leakage and standard flow rate. The method deviates from the theoretical leakage values by less than 3% full scale (FS), and shows a good precision and scope compared with traditional flow measurements. In addition, the proposed parallel connection based on standard flow makes operation easy and measuring fast possibly, thus the method can be applied in the new area of pneumatic energy saving industry.
-
Key words:
- flow rate /
- tracking /
- leakage /
- flow measurement
-
[1] Raišutis R.Investigation of the flow velocity profile in a metering section of an invasive ultrasonic flowmeter[J].Flow Measurement and Instrumentation,2006,17(4):201-206 [2] Zhang Hongjian,Huang Yongmei,Sun Zhiqiang.A study of mass flow rate measurement based on the vortex shedding principle[J].Flow Measurement and Instrumentation,2006 17(1): 29-38 [3] Clark C,Cheesewright R,Wang Shiwen.Prediction of the dynamic performance of fast response Coriolis meter systems[J].IEEE Transaction on Instrumentation and Measurement,2008,57(1):95-99 [4] Sahu O P,Anil K.Measurement of distance and medium velocity using frequency-modulated ultrasound[J].IEEE Transaction on Instrumentation and Measurement,2008,57(4):838-842 [5] Dharshanie V M,Roger C B,Jim W.Further studies of the accuracy of clamp-on transit-time ultrasonic flow meters for liquids[J].IEEE Transaction of Instrumentation and Measurement,2009,58(4):1602-1609 [6] 江洋,龚其春,叶骞,等.气体泄漏量超声检测理论分析及实验 [J].上海交通大学学报,2006,40(2):224-226 Jiang Yang,Gong Qichun,Ye Qian,et al.The theory analysis and experiments of using ultrasonic to inspect the leak amount [J].Journal of Shanghai Jiaotong University,2006,40(2):224-226 (in Chinese) [7] 葛楠,彭光正,纪春华.气体泄漏传热模型及其有限元分析[J].传感技术学报,2008,21(12):2005-2008 Ge Nan,Peng Guangzheng,Ji Chunhua.Heat transfer method of air leak and its finite element analysis [J].Chinese Journal of Sensors and Actuators,2008,21(12):2005-2008 (in Chinese) [8] Povey T,Beard P F.A novel experimental technique for accurate mass flow rate measurement [J].Flow Measurement and Instrumentation,2008,19(5):251-259 [9] Kawashima K,Kagawa T,Fujita T.Instantaneous flow rate measurement of idea gases [J].Journal of Dynamic Systems,Measurement and Control,2000,122 (1):174-178 [10] Bascetta L,Magnani G.Velocity estimation:assessing the performance of non-model based techniques [J].IEEE Transaction on Control System Technology,2009,17(2):424-433 [11] Su Y X,Zheng C H,Mueller P C,et al.A simple improved velocity estiamtion for low-speed regions based on position measurements only[J].IEEE Transaction on Control System Technology,2006,14(5):937-942
点击查看大图
计量
- 文章访问数: 2599
- HTML全文浏览量: 151
- PDF下载量: 524
- 被引次数: 0