Experiment of multi-component hydrocarbon fuels RP-3 thermal conductivity
-
摘要: 基于经典的瞬态热线法原理,设计研制了一种适用于高温高压条件下测量多组分碳氢燃料导热系数的实验装置.对无水乙醇、甲苯及高压氮气进行了标定,结果表明液相导热系数最大偏差在1%以内,气相导热系数最大偏差在3%以内.进而对国产碳氢燃料RP-3导热系数进行了测定,温度范围298~430 K,压力范围0.1~5 MPa.改进和完善了超临界压力下流体导热系数的测量方法.Abstract: Based on the classic trasient hot-wire princeple, the experiment apparatus for the measurement of multicomponent hydrocarbon fuel thermal conductivity under high temperature and high pressure was introduced. The calibration results of absolute ethyl alcohol, toluene and high pressure nitrogen show that the maxmum deviation for liquid thermal conductivity is less than 1% and for gas is less than 3%. After that, conductivity of domestic hydrocarbon fuel RP-3 was measured under 298~430 K and 0.1~5 MPa using this apparatus and the results show a good repeatibility. It is of great importance to improve conductivity measuring mehtods for fluid under super-critical pressure.
-
Key words:
- transient hot-wire /
- hydrocarbon fuels /
- RP-3 /
- thermophysical properties /
- thermal conductivity
-
[1] Bruening G B,Chang W S.Cooled cooling air systems for turbine thermal management [R].ASME Paper 1999-GT-14,1999 [2] Healy J J,De Groot J J,Kestin J.The theory of the transient hot-wire method for measuring thermal conductivity [J].Physica,1976,82C:392-408 [3] Carslaw H 5,Jaeger J C.Conduction of heat in solids[M].2nd ed.London:Oxford University Press,1959, 510 [4] Wakeham W A,Nagashima A,Sengers J V.Experimental thermo dynamics,volume III:measurement of the transport properties of fluids[M].Oxford:Blackwell Scientific Publications,1991 [5] Yan Qiuhui,Liu Zhigang ,Yin Jianmin.On the thermal conductivity coefficient of fluid by the transient hot-wire technique [J].J Xi-an Univ of Arch & Tech,1997,29(3):322-325 [6] Wang Yugang,Wu Jiangtao,Liu Zhigang.Thermal conductivity of dimethyl ether in saturated liquid phase [J]. Journal of Xi-an Jiaotong University,2005,39(9):1026-1029 [7] Shi Lin,Liu Xiaojun,Duan Yuanyuan.Transport properties of 1,1,1,2,3,3,3-heptafluoropropane (HFC-227ea) [J] .Tingshua Univ:Sci & Tech,2001,41(6):81-84 [8] Zhang Hongwu,Pan Jiang,Wang Yugang.Development of experimental systems for measurement of liquid thermal conductivity by the transient hot-wire technique [J].Journal of China University Metrology, 2010,21(4):283-288 [9] Liu Ming,He Chaohong,Huang Zhiyao.Measurement of thermal conductivity for systems of methyl ethyl ketoxime with methyl ethyl ketone and n-hexane separately[J] .Journal of Chemical Engineering of Chinese Universities,2011,25(4):547-553 [10] Ni Xinlei.Research on output characteristic research of unbalanced bridge[J].College Physics,2009,28(3):33-35 [11] Liu Gaungqi,Ma Lianxiang,Liu Jie.Handbook of chemistry and chemical property data [M].Beijing:Chemical Industry Press,2002 [12] Ramires M L V,Nieto de Castro C A,Perkins R A ,et al.Reference data for the thermal conductivity of saturated liquid toluene over a wide range of temperatures[J].J Phys Chem Ref Data,2000,29(2):133-139 [13] Stephan K,Krauss R.Viscosity and thermal conductivity of nitrogen for a wide range of fluid States[J].Jphy Chem Ref Data,1987,16(4):993-1023 [14] Song Shoupeng.Digital filter design and application [M].Zhenjiang: Jiangsu University Press,2009:182
点击查看大图
计量
- 文章访问数: 1618
- HTML全文浏览量: 194
- PDF下载量: 585
- 被引次数: 0