Experiments of separated structure mechanical vapor compression system
-
摘要: 针对传统机械压汽蒸馏的不足,提出分离式机械压汽蒸馏系统.建立了一套容量为1.5 m3/d的单效分离式机械压汽蒸馏系统并对其进行实验研究.实验系统主要由两套旋转蒸发器、冷凝器以及压缩机组成.通过改变压缩机转速和蒸发温度来研究系统的性能.结果表明在蒸馏水产量一定的前提下压缩机进口压力和冷凝器进口压力随着压缩机转速的增加而逐渐下降,换热温差随着压缩机转速的增加而增加,最高温差稳定在8.5℃左右.通过改变系统的真空度获得不同的蒸发温度,蒸发温度越高,蒸馏产量越高,系统性能也越好.Abstract: Due to the disadvantages of the traditional mechanical vapor compression (MVC) system, a new MVC system which has the separated structure was presented. The new system was studied experimentally on a single effect system with a rated capacity of 1.5 m3/d. The experiment system consists of two sets of rotating evaporators, condenser and compressor. The performance of the system was evaluated at different compressor speeds and evaporating temperatures. It shows that the compressor and condenser inlet pressures fall gradually with the increases in compressor speed under a constant distillate production. However, the temperature difference increases with the increase in compressor speed, and the value of the highest temperature difference is stabilized at around 8.5℃. The different evaporating temperatures were obtained by the variation of the vacuum. Increasing the evaporating temperature enhances the production, and the performance is better with higher evaporating temperature.
-
[1] Ettouney H, El-Dessouky H,Al-Roumi Y.Analysis of mechanical vapor compression desalination process[J].International Journal of Energy Research,1999,23(5):431-451 [2] Josa M V. Mechanical vapour compression desalination plants:a case study[J].Desalination,1995,101(1):1-10 [3] Hisham E. Design of single-effect mechanical vapor compression[J].Desalination,2006,190(1-3):1-15 [4] Bahar R, Hawlader M N A,Woei L S.Performance evaluation of a mechanical vapor compression desalination system[J].Desalination,2004,166(1-3):123-127 [5] 焦冬生,王军. 机械压汽蒸馏海水淡化系统的实验研究[J].水处理技术,2007,33(7):37-40 Jiao Dongsheng,Wang Jun.Experimental study of the mechanical vapor compression desalination[J].Technology of Water Treatment,2007,33(7):37-40(in Chinese) [6] 焦冬生,王军. 机械压汽蒸馏海水淡化系统的性能分析[J].中国科学技术大学学报,2009,39(1):76-82 Jiao Dongsheng,Wang Jun.Performance of the mechanical vapor compression desalination system[J].Journal of University of Science and Technology of China,2009,39(1):76-82(in Chinese) [7] Liang L, Han D,Ma R,et al.Treatment of high-concentration wastewater using double-effect mechanical vapor recompression[J].Desalination,2013,314:139-146 [8] Mabrouk A A, Nafey A S,Fath H E S.Thermoeconomic analysis of some existing desalination processes[J].Desalination,2007,205(1-3):354-373 [9] Kronenberg G, Lokiec F.Low-temperature distillation processes in single-and dual-purpose plants[J].Desalination,2001,136(1-3):189-197 [10] El-Dessouky H T, Ettouney H M.Fundamentals of salt water desalination[M].Amsterdam:Elsevier,2002:670 [11] Lukic N, Diezel L L,Frba A P,et al.Economical aspects of the improvement of a mechanical vapor compression desalination plant by dropwise condensation[J].Desalination,2010,264(1/2):173-178 [12] Wang C S, Greif R,Laird A D K.Heat transfer in a rotating disk evaporator[J].Desalination,1980,33(1-3):259-267 [13] Labib M N, Kim S S,Choi D,et al.Numerical investigation of the effect of inlet skew angle on the performance of mechanical vapor compressor[J].Desalination,2012,284:66-76 [14] 郑群,牛利民. 不同工质离心压缩机的性能模化[J].应用科技,1993(2):55-60 Zhen Qun,Niu Limin.The centrifugal compressor's performance modeling for different medium[J].Applied Science and Technology,1993(2):55-60(in Chinese) [15] Alasfour F N, Abdulrahim H K.The effect of stage temperature drop on MVC thermal performance[J].Desalination,2011,265(1-3):213-221
点击查看大图
计量
- 文章访问数: 1399
- HTML全文浏览量: 280
- PDF下载量: 385
- 被引次数: 0