Application of synthetic aperture focusing technique to defect quantification for immersion ultrasonic testing
-
摘要: 针对水浸超声检测常用缺陷定量方法存在成本高或缺陷定量误差较大的问题,提出一种将原始检测数据经频域合成孔径聚焦技术(FSAFT)处理后再运用半波高法进行缺陷定量评价(FSAFT-DQM)的新方法。建立了水浸超声点聚焦探头FSAFT成像方法,制备了横通孔和平底孔试样,开展了FSAFT-DQM缺陷定量评价试验研究。试验结果表明:FSAFT-DQM缺陷定量精度受检测深度影响不明显;当扫描步距不大于探头中心频率对应的半波长时,与半波高法相比,平底孔试样FSAFT-DQM缺陷定量误差由71.9%降低到10.0%以内;扫描步距在探头中心频率对应的半波长到波长之间时,图像频域插值算法将平底孔试样FSAFT-DQM缺陷定量误差由17.2%降低到5.6%。研究结果表明:FSAFT-DQM能有效提高缺陷定量精度。
-
关键词:
- 水浸超声检测 /
- 缺陷定量评价 /
- 点聚焦探头 /
- 频域合成孔径聚焦技术(FSAFT) /
- 半波高法
Abstract: Among the common defect quantification methods for immersion ultrasonic testing, some are high cost while others have relatively large quantitative error. Given the problem, a new 6 dB drop defect quantification method based on frequency domain synthetic aperture focusing technique (FSAFT-DQM) was studied. The FSAFT imaging method for spherically focused transducer used by immersion ultrasonic testing was established. Experiments conducted on specimens containing either circular cylindrical cavities or flat bottom hole show that defect depth has little effect on FSAFT-DQM's accuracy; compared with 6 dB drop method, flat bottom hole's quantitative error of FSAFT-DQM drops from 71.9% to within 10.0% with step length below half-wavelength of transducer's center frequency and the error decreases from 17.2% to 5.6% by image interpolation algorithm with step length between half-wavelength and wavelength. The research results show that FSAFT-DQM improves the precision of defect quantification effectively. -
[1] THOMPSON R B.Quantitative ultrasonic nondestructive evaluation methods[J].Journal of Applied Mechanics,1983,50(4b):1191-1201. [2] 郑中兴.第四专题超声检测中缺陷的定量[J].无损检测,1994,16(2):52-57.ZHENG Z X.Quantitative evaluation of flaws in ultrasonic testing[J].Nondestructive Testing,1994,16(2):52-57(in Chinese). [3] 史亦韦.超声检测[M].北京:机械工程出版社,2005:119-126.SHI Y W.Ultrasonic testing[M].Beijing:China Machine Press,2005:119-126(in Chinese). [4] SILK M G.Defect detection and sizing in metals using ultrasound[J].International Materials Reviews,1982,27(1):28-50. [5] 胡宏伟,彭凌兴,周正干,等.曲面构件水浸超声检测缺陷定量研究[J].航空学报,2014,35(11):3166-3173.HU H W,PENG L X,ZHOU Z G,et al.Quantitative research on defect of curved components with immersion ultrasonic testing[J].Acta Aeronautica et Astronautica Sinica,2014,35(11):3166-3173(in Chinese). [6] 王铮,梁菁,史丽军,等.复合材料层板超声检测缺陷评定方法分析[J].南京航空航天大学学报,2012,44(S):138-141.WANG Z,LIANG J,SHI L J,et al.Measurement for ultrasonic contact inspection on defect in carbon fiber-reinforced composite[J].Journal of Nanjing University of Aeronautics & Astronautics,2012,44(S):138-141(in Chinese). [7] SCHMERR L W.Fundamental of ultrasonic nondestructive evaluation[M].New York:Plenum Press,1998:181-197. [8] BUSSE L J,COLLINS H D,DOCTOR S R.Review and discussion of the development of synthetic aperture focusing technique for ultrasonic testing (SAFT-UT):NUREG/CR-3625[R].Richland:Pacific Northwest Lab,1984. [9] FREDERICK J R,SEYDEL J A,FAIRCHILD R C.Improved ultrasonic non-destructive testing of pressure vessels:NUREG-O007-1[R].Ann Arbor:University of Michigan,1976. [10] BUSSE L J.Three-dimensional imaging using a frequency-domain synthetic aperture focusing technique[J].IEEE Transactions on Ultrasonics,Ferroelectrics,and Frequency Control,1992,39(2):174-179. [11] STEPINSKI T.An implementation of synthetic aperture focusing technique in frequency domain[J].IEEE Transactions on Ultrasonics,Ferroelectrics,and Frequency Control,2007,54(7):1399-1408. [12] 吴施伟,吴海腾,金浩然,等.聚焦探头水浸检测下的频域合成孔径聚焦技术[J].浙江大学学报(工学版),2015,49(1):110-115.WU S W,WU H T,JIN H R,et al.Frequency-domain synthetic aperture focusing technique for immersion testing using focused transducer[J].Journal of Zhejiang University (Engineering Science),2015,49(1):110-115(in Chinese). [13] ROSE J L.Ultrasonic waves in solid media[M].Cambridge:Cambridge University Press,2004:24-26. [14] GOODMAN J W.Introduction to Fourier optics[M].New York:McGraw-Hill,1996:55-58. [15] LEVESQUE D,BLOUIN A,NERON C,et al.Performance of laser-ultrasonic F-SAFT imaging[J].Ultrasonics,2002,40(10):1057-1063. [16] SCHMERR L W,SONG S J.Ultrasonic nondestructive evaluation system:Models and measurements[M].New York:Springer Science & Business Media,2007:152-153.
点击查看大图
计量
- 文章访问数: 902
- HTML全文浏览量: 39
- PDF下载量: 732
- 被引次数: 0