Volume 39 Issue 6
Jun.  2013
Turn off MathJax
Article Contents
Gong Hui, Tian Guoliang, Yu Tao, et al. Cross calibration of CCD cameras in HJ satellite based on the image simulation[J]. Journal of Beijing University of Aeronautics and Astronautics, 2013, (6): 818-822. (in Chinese)
Citation: Gong Hui, Tian Guoliang, Yu Tao, et al. Cross calibration of CCD cameras in HJ satellite based on the image simulation[J]. Journal of Beijing University of Aeronautics and Astronautics, 2013, (6): 818-822. (in Chinese)

Cross calibration of CCD cameras in HJ satellite based on the image simulation

  • Received Date: 27 Jun 2012
  • Publish Date: 30 Jun 2013
  • As to two CCD cameras in the same HJ-1 satellite, a new cross calibration method was proposed based on image simulation. Through the method, un-calibrated CCD without obtaining the image of a target was cross-calibrated by calibrated CCD covering the target by analyzing the mathematical relation of digital counts between two CCD cameras. The calibration coefficients of A2CCD and B2CCD in October 2008 were achieved with the method and validated by using field experiment data of Gongger test site and MODIS data of Dunhuang test site. Principal error sources of the method were analyzed. The results show that the method has high precision and reliability. This method can increase the frequency of calibration besides ensuring the precision of the calibration.

     

  • loading
  • [1]
    Kaufman Y J,Holben B N.Calibration of the AVHRR visible and near-IR bands by atmospheric scattering,ocean glint,and desert reflection [J].International Journal of Remote Sensing,1993,14:21-52
    [2]
    Gu X F,Guyot G,Verbrugghe M.Evaluation of measurement errors in ground surface reflectance for satellite calibration [J].International Journal of Remote Sensing,1992,13:2531-2546
    [3]
    Slater P N,Biggar S F,Holm R G,et al.Reflectance-and radiance-based methods for the in-flight absolute calibration of multispectral sensors [J].Remote Sensing of Environment,1987,22:11-37
    [4]
    Chander G,Helder D L,Markham B.Landsat-5 TM reflective band absolute radiometric calibration [J].IEEE Transaction on Geoscience and Remote Sensing,2004,42(12):2747-2760
    [5]
    Vermote E,Kaufman Y J.Absolute calibration of AVHRR visible and near-infrared channels using ocean and cloud views [J].International Journal of Remote Sensing,1995,16(13):2317-2340
    [6]
    Teillet P M,Barker J L,Markham B L,et al.Radiometric cross-calibration of the Landsat-7 ETM+ and Landsat-5 TM sensors based on tandem data sets [J].Remote Sensing of Environment,2001,78:39-54
    [7]
    Slater P N,Biggar S F,Thome K J,et al.Vicarious radiometric calibration of EOS sensors [J].Journal of Atmospheric and Ocean Technolgy,1996,13:349-359
    [8]
    Xiong X X,Sun J Q,Barnes W,et al.Multiyear on-orbit calibration and performance of Terra MODIS reflective solar bands [J].IEEE Transactions of Geoscience and Remote Sensing,2007,45(4):879-889